ABB Powervalue 11 Tower G2 1KVA 900W Online UPS Tower

Categories: ,
Estimated delivery on 29 June - 1 July, 2026
Description   ABB PowerValue 11T G2 Single-phase UPS from 1 kVA to 10 kVA ABB’s PowerValue 11T G2 is a single-phase in/out, double conversion online uninterruptible power supply (UPS) that guarantees up to 10 kW per single UPS of clean, reliable power for your critical single-phase applications. As well as maintaining power to your server room, advertising display, turnstiles, lab equipment, transportation signaling systems, ATM or vending machine, the PowerValue 11T G2 also conditions incoming power to eliminate spikes, swells, sags, noise and harmonics. Featuring voltage and frequency independent (VFI) topology, the tower-only PowerValue 11T G2 saves costs by minimizing energy losses with its double conversion efficiency of up to 95 percent (up to 98% in ECO mode). Two or three units can be connected in parallel to boost power delivery to a maximum of 30 kW or to provide redundancy. Simple to install or maintain, inexpensive to run and with the most compact online UPS footprint available on the market, the PowerValue 11T G2 provides stable, regulated, transient-free, pure sine wave AC power with extremely tight output voltage regulation. All units can be fitted with up to four external battery modules (EBMs) to extend runtime to well over two hours. Each EBM is dedicated to its corresponding UPS and setup is easily accomplished via the LCD menu. Technical specifications   GENERAL DATA G2 1kVA B Output rated power 900 W Output power factor 0.9 Topology Online double conversion Parallel configuration No Inbuilt batteries Yes/No INPUT Nominal input voltage 220/230/240 VAC Input voltage tolerance 100-300 VAC (load dependent) Input current THDi 5% with full resistive load Frequency range 45-55 Hz / 54-66 Hz Power factor ≥0.99 OUTPUT Rated output voltage 220/230/240 VAC Voltage tolerance ±1% (referred to 230V Voltage distortion <2% linear load, <6% non linear load Overload capacity (linear load) on inverter 60s: 106-130% load 10s: 131-150% load 300ms: ≥ 150% load Nominal frequency 50 or 60 Hz Crest factor 3:1 (load supported) EFFICIENCY Overall system efficiency Up to 89% In eco-mode Up to 97.5% Protection rating IP20 Storage temperature UPS: -25°C to 60°C; Batteries: 0°C to 35°C Relative humidity 0% to 95% Altitude (above see level) 1000m without derating BATTERIES Type VRLA (valve regulated lead-acid) Inbuilt batteries 2×9.4 Ah (B) Charging current 1.5A/3-6A adjustable Recharge time (inbuilt batteries) 4h to 90% COMMUNICATIONS User interface LCD display Optional communication cards SNMP;ModBus;AS400;Environmental monitoring sensor probe STANDARDS Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Performance IEC/EN 62040-3 Manufacturing ISO 9001:2015, ISO 14001:2015, OHSAS 18001 WEIGHT, DIMENSIONS Weight 9.2/3.9 Kg Dimensions w x h x d 144x228x356 mm 102x228x346mm Warranty *2yrs warranty on parts and service