ABB PowerValue 11T G2 2kVA/2000W Online UPS 230V

Categories: ,
Estimated delivery on 29 June - 1 July, 2026
Description   The PowerValue 11T G2 with its tested and cost-effective ABB UPS technology offers high-performance, now made available to market sectors with lower power requirements: Small server rooms, critical lab or industrial equipment, security installations. Applications of a similar power class can now profit from one of 12 PowerValue 11T G2 models. With the most compact online UPS footprint available, the PowerValue 11T G2 features true on-line double conversion technology. This provides a flexible output frequency and isolates the UPS from upstream disturbances so that the critical load sees only stable, well-regulated, transient-free, pure sine wave AC power. A rated output power factor up to 1.0 (kVA = kW – for 6 & 10kVA), means the PowerValue 11T G2 delivers 11 percent more active power than a UPS with a power factor of 0.9. The UPS is optimized for modern IT loads and helps users reduce their energy budget with its double conversion efficiency of up to 95 percent (up to 98% in ECO mode). • Low input line disturbances: input PF ≥ 0.995 @ 100 percent linear load – THDi  < 3 percent • Flexible configuration for scalable runtime: UPS and EBMs with and without batteries (long backup) • Adjustable DC voltage and battery charger current • Digital charger technology provides accurate charger current setting and reduces charger ripple current • The UPS is delivered with an inbuilt parallel board and paralleling cables. No additional hardware is required for this installation (6 & 10kVA). All this with the same guaranteed high availability and quality standards as ABB’s higher-power premium UPS models – and at the most attractive entry level price  round. • Two Years Warranty on Electronic Parts, One Year Batteries.   Specifications Standard • Tower-type, IP20 UPS enclosure • Single-phase in and out • Online double conversion UPS • Paralleling up to three units allows for increase of capacity to 30 kW or redundancy  (6-10 kVA only) • Operator and status LCD • Wide voltage input frequency range • Inbuilt batteries (B/B2 versions only) • Maintenance bypass switch (6-10 kVA only) • Plug-and-play • Autonomy: 8/15 minutes @ 75/50% load     SPECS Topology Online double conversion Inbuilt batteries Yes INPUT Nominal input voltage 220/230/240 VAC Input voltage tolerance 100-300 VAC (load dependent) Input current THDi 5% with full resistive load Frequency range 45-55 Hz / 54-66 Hz OUTPUT Rated output voltage 220/230/240 VAC Voltage tolerance ±1% (referred to 230V) Voltage distortion <2% linear load, <6% non linear load Overload capacity (linear load) on inverter 60s: 106-130% load 10s: 131-150% load 300ms: ≥ 150% load Nominal frequency 50 or 60 Hz Crest factor 3:1 (load supported) EFFICIENCY Overall system efficiency Up to 91% In eco-mode Up to 98% ENVIRONMENT Protection rating IP20 Storage temperature UPS: -25°C to 60°C; Batteries: 0°C to 35°C Operating temperature 0°C to 40°C Relative humidity 0% to 95% Altitude (above see level) 1000m without derating BATTERIES Type VRLA (valve regulated lead-acid) Inbuilt batteries 4×9.4Ah Charging current 1.5A/1.5-6A adjustable Recharge time (inbuilt batteries) 4h to 90% COMMUNICATIONS User interface LCD display Optional communication cards SNMP;ModBus;AS400;Environmental monitoring sensor probe STANDARDS Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Performance IEC/EN 62040-3 Manufacturing ISO 9001:2015, ISO 14001:2015, OHSAS 18001 WEIGHT, DIMENSIONS Weight 17.4 Dimensions w x h x d 190x327x399 mm